Diagnosis and treatment of adult flatfoot MS Lee, JV Vanore, JL Thomas, AR Catanzariti, G Kogler, SR Kravitz, ... The Journal of Foot and Ankle Surgery 44 (2), 78-113, 2005 | 374 | 2005 |
A portable powered ankle-foot orthosis for rehabilitation. KA Shorter, GF Kogler, E Loth, WK Durfee, ET Hsiao-Wecksler Journal of Rehabilitation Research & Development 48 (4), 2011 | 252 | 2011 |
Biomechanics of longitudinal arch support mechanisms in foot orthoses and their effect on plantar aponeurosis strain GF Kogler, SE Solomonidis, JP Paul Clinical biomechanics 11 (5), 243-252, 1996 | 243 | 1996 |
Technologies for powered ankle-foot orthotic systems: Possibilities and challenges KA Shorter, J Xia, ET Hsiao-Wecksler, WK Durfee, GF Kogler IEEE/ASME Transactions on mechatronics 18 (1), 337-347, 2011 | 160 | 2011 |
A pneumatic power harvesting ankle-foot orthosis to prevent foot-drop R Chin, ET Hsiao-Wecksler, E Loth, G Kogler, SD Manwaring, SN Tyson, ... Journal of neuroengineering and rehabilitation 6, 1-11, 2009 | 136 | 2009 |
The influence of medial and lateral placement of orthotic wedges on loading of the plantar aponeurosis. An in vitro study GF Kogler, FB Veer, SE Solomonidis, JP Paul JBJS 81 (10), 1403-13, 1999 | 121 | 1999 |
Novel methods for sensing acoustical emissions from the knee for wearable joint health assessment CN Teague, S Hersek, H Töreyin, ML Millard-Stafford, ML Jones, ... IEEE Transactions on Biomedical Engineering 63 (8), 1581-1590, 2016 | 102 | 2016 |
In vitro method for quantifying the effectiveness of the longitudinal arch support mechanism of a foot orthosis GF Kogler, SE Solomonidis, JP Paul Clinical Biomechanics 10 (5), 245-252, 1995 | 87 | 1995 |
Posterior tibial tendon dysfunction KM Supple, JR Hanft, BJ Murphy, CJ Janecki, GF Kogler Seminars in arthritis and rheumatism 22 (2), 106-113, 1992 | 67 | 1992 |
Portable active pneumatically powered ankle-foot orthosis ET Hsiao-Wecksler, KA Shorter, V Gervasi, DL Cook, R Remmers, ... US Patent 9,480,618, 2016 | 59 | 2016 |
Static structural testing of trans-tibial composite sockets TA Current, GF Kogler, DG Earth Prosthetics and orthotics international 23 (2), 113-122, 1999 | 58 | 1999 |
The Effect of Heel Elevation on Strain Within the Plantar Aponeurosis: In Vitro Study GF Kogler, FB Veer, SJ Verhulst, SE Solomonidis, JP Paul Foot & ankle international 22 (5), 433-439, 2001 | 56 | 2001 |
Acoustic emissions as a non-invasive biomarker of the structural health of the knee DC Whittingslow, HK Jeong, VG Ganti, NJ Kirkpatrick, GF Kogler, OT Inan Annals of biomedical engineering 48, 225-235, 2020 | 45 | 2020 |
Acoustical emission analysis by unsupervised graph mining: A novel biomarker of knee health status S Hersek, MB Pouyan, CN Teague, MN Sawka, ML Millard-Stafford, ... IEEE Transactions on Biomedical Engineering 65 (6), 1291-1300, 2017 | 40 | 2017 |
Experimental evaluation of a portable powered ankle-foot orthosis KA Shorter, Y Li, EA Morris, GF Kogler, ET Hsiao-Wecksler 2011 Annual International Conference of the IEEE Engineering in Medicine and …, 2011 | 34 | 2011 |
Portable active fluid powered ankle-foot orthosis ET Hsiao-Wecksler, JN Gilmer, G Kogler, E Loth, KA Shorter, JE Thomas US Patent App. 12/898,519, 2011 | 31 | 2011 |
Materials and technology GF Kogler, M Bridges, JE Hilliard, KK Chui Lusardi MM, Nielsen CC. Orthotics and prosthetics in rehabilitation. Woburn …, 2000 | 28 | 2000 |
Wearable knee health system employing novel physiological biomarkers OT Inan, DC Whittingslow, CN Teague, S Hersek, MB Pouyan, ... Journal of Applied Physiology 124 (3), 537-547, 2018 | 23 | 2018 |
Symmetrical kinematics does not imply symmetrical kinetics in people with transtibial amputation using cycling model WL Childers, GF Kogler J Rehabil Res Dev 51 (8), 1243-1254, 2014 | 23 | 2014 |
The influence of metatarsal support height and longitudinal axis position on plantar foot loading TH Brodtkorb, GF Kogler, A Arndt Clinical Biomechanics 23 (5), 640-647, 2008 | 22 | 2008 |