Functional electrical stimulation and spinal cord injury CH Ho, RJ Triolo, AL Elias, KL Kilgore, AF DiMarco, K Bogie, AH Vette, ... Physical Medicine and Rehabilitation Clinics 25 (3), 631-654, 2014 | 274 | 2014 |
Muscle selection and walking performance of multichannel FES systems for ambulation in paraplegia R Kobetic, RJ Triolo, EB Marsolais IEEE Transactions on rehabilitation engineering 5 (1), 23-29, 1997 | 259 | 1997 |
Implanted functional electrical stimulation system for mobility in paraplegia: a follow-up case report R Kobetic, RJ Triolo, JP Uhlir, C Bieri, M Wibowo, G Polando, ... IEEE Transactions on Rehabilitation Engineering 7 (4), 390-398, 1999 | 224 | 1999 |
Development of hybrid orthosis for standing, walking, and stair climbing after spinal cord injury. R Kobetic, CS To, JR Schnellenberger, ML Audu, TC Bulea, R Gaudio, ... Journal of Rehabilitation Research & Development 46 (3), 2009 | 208 | 2009 |
A model of selective activation of the femoral nerve with a flat interface nerve electrode for a lower extremity neuroprosthesis MA Schiefer, RJ Triolo, DJ Tyler IEEE transactions on neural systems and rehabilitation engineering 16 (2 …, 2008 | 169 | 2008 |
Architecture of the rectus abdominis, quadratus lumborum, and erector spinae SL Delp, S Suryanarayanan, WM Murray, J Uhlir, RJ Triolo Journal of biomechanics 34 (3), 371-375, 2001 | 156 | 2001 |
New functional electrical stimulation approaches to standing and walking VK Mushahwar, PL Jacobs, RA Normann, RJ Triolo, N Kleitman Journal of neural engineering 4 (3), S181, 2007 | 152 | 2007 |
Clinical applications of electrical stimulation after spinal cord injury GH Creasey, CH Ho, RJ Triolo, DR Gater, AF DiMarco, KM Bogie, ... The journal of spinal cord medicine 27 (4), 365-375, 2004 | 151 | 2004 |
Consumer perspectives on mobility: implications for neuroprosthesis design. DL Brown-Triolo, MJ Roach, K Nelson, R Triolo Journal of Rehabilitation Research & Development 39 (6), 2002 | 150 | 2002 |
Selective stimulation of the human femoral nerve with a flat interface nerve electrode MA Schiefer, KH Polasek, RJ Triolo, GCJ Pinault, DJ Tyler Journal of neural engineering 7 (2), 026006, 2010 | 149 | 2010 |
Preliminary performance of a surgically implanted neuroprosthesis for standing and transfers--where do we stand? JA Davis Jr, RJ Triolo, J Uhlir, C Bieri, L Rohde, D Lissy, S Kukke Journal of Rehabilitation Research & Development 38 (6), 2001 | 134 | 2001 |
Fascicular anatomy of human femoral nerve: implications for neural prostheses using nerve cuff electrodes KJ Gustafson, GCJ Pinault, JJ Neville, I Syed, JA Davis Jr, J Jean-Claude, ... Journal of rehabilitation research and development 46 (7), 973, 2009 | 132 | 2009 |
Experimental evaluation of an adaptive feedforward controller for use in functional neuromuscular stimulation systems JJ Abbas, RJ Triolo IEEE Transactions on Rehabilitation Engineering 5 (1), 12-22, 1997 | 131 | 1997 |
Walking after incomplete spinal cord injury using an implanted FES system: a case report. E Hardin, R Kobetic, L Murray, M Corado-Ahmed, G Pinault, J Sakai, ... Journal of Rehabilitation Research & Development 44 (3), 2007 | 114 | 2007 |
Long-term user perceptions of an implanted neuroprosthesis for exercise, standing, and transfers after spinal cord injury. S Agarwal, RJ Triolo, R Kobetic, M Miller, C Bieri, S Kukke, L Rohde, ... Journal of Rehabilitation Research & Development 40 (3), 2003 | 112 | 2003 |
High-density peripheral nerve cuffs restore natural sensation to individuals with lower-limb amputations H Charkhkar, CE Shell, PD Marasco, GJ Pinault, DJ Tyler, RJ Triolo Journal of Neural Engineering 15 (5), 056002, 2018 | 110 | 2018 |
Effects of regular use of neuromuscular electrical stimulation on tissue health. KM Bogie, RJ Triolo Journal of Rehabilitation Research & Development 40 (6), 2003 | 105 | 2003 |
Long-term stability of stimulating spiral nerve cuff electrodes on human peripheral nerves BP Christie, M Freeberg, WD Memberg, GJC Pinault, HA Hoyen, DJ Tyler, ... Journal of neuroengineering and rehabilitation 14, 1-12, 2017 | 99 | 2017 |
Implanted functional neuromuscular stimulation systems for individuals with cervical spinal cord injuries: clinical case reports RJ Triolo, C Bieri, J Uhlir, R Kobetic, A Scheiner, EB Marsolais Archives of physical medicine and rehabilitation 77 (11), 1119-1128, 1996 | 99 | 1996 |
Chronic stability and selectivity of four-contact spiral nerve-cuff electrodes in stimulating the human femoral nerve LE Fisher, DJ Tyler, JS Anderson, RJ Triolo Journal of neural engineering 6 (4), 046010, 2009 | 96 | 2009 |