Automated detection of rotor faults for inverter-fed induction machines under standstill conditions B Kim, K Lee, J Yang, SB Lee, EJ Wiedenbrug, MR Shah IEEE Transactions on Industry Applications 47 (1), 55-64, 2010 | 94 | 2010 |
A new strategy for condition monitoring of adjustable speed induction machine drive systems SB Lee, J Yang, J Hong, JY Yoo, B Kim, K Lee, J Yun, M Kim, KW Lee, ... IEEE Transactions on Power Electronics 26 (2), 389-398, 2010 | 71 | 2010 |
Evaluation of the detectability of broken rotor bars for double squirrel cage rotor induction motors J Park, B Kim, J Yang, SB Lee, EJ Wiedenbrug, M Teska, S Han 2010 IEEE Energy Conversion Congress and Exposition, 2493-2500, 2010 | 65 | 2010 |
Experimental evaluation of using the surge PD test as a predictive maintenance tool for monitoring turn insulation quality in random wound AC motor stator windings J Yang, T Kang, B Kim, SB Lee, YW Yoon, D Kang, J Cho, H Kim IEEE transactions on dielectrics and electrical insulation 19 (1), 53-60, 2012 | 35 | 2012 |
Development of 50kW traction induction motor for electric vehicle (EV) B Kim, J Lee, Y Jeong, B Kang, K Kim, Y Kim, Y Park 2012 IEEE Vehicle Power and Propulsion Conference, 142-147, 2012 | 25 | 2012 |
In-service monitoring of stator-slot magnetic wedge condition for induction motors S Han, J Jung, KW Lee, SB Lee, S Nandi, B Kim, B Kang IEEE Transactions on Industry Applications 52 (4), 2900-2910, 2016 | 14 | 2016 |